3) Compressor
4) Condenser Defrost
5) Cool Mode Antifreeze
6) Inverter
7) Alarm and Contact
Please refer to 8. APPENDIX for detail desciption.
28
C1 Min Run : 12s
C2 Min Stop : 240s
C3 2On Interval : 360s
C4 2Cp ON Dly : 15s
C5 P-Cp ON Dly : 60s
C6 Cp-P OFF Dly: 40°C
C7 Cp Cut Off : 120°C
D1 Start Temp : -3°C
D2 End Temp : 14°C
D3 Max Dura : 10m
D4 Interval : 45m
D5 Dly Bfr Def : 0s
D6 Dly Aft Def : 0s
A
1 Heater SP : C
A2 Heater Diff : 2.0°C
A3 Sensor : Leave
A4 Alarm SP : 3°C
A5 Alarm Diff : 2.0°C
V
1 Cp Freq : 100Hz
V2 EXV : 180
V3 Cp Manual : Disable
V4 EXV Manual : Disable
V5 Def Mode : Disable
P1 FS Confirm : 5s
P2 FS Delay : 180s
P3 LP Delay : 30s
P4 CO Reset : Manual
P5 HP Reset : Auto
P6 LP Reset : Auto
P7 FO Reset : Manual
P8 RO Reset : Manual
P9 FS Reset : Manual
P10 Aux Reset : Manual
P11 A/F Reset : Manual
P12 CO Contact : Normal
P13 HP Contact : Normal
P14 LP Contact : Normal
P15 FO Contact : Normal
P16 PO Contact : Normal
P17 FS Contact : Normal
P18 EA Contact : Normal