Heating Heat Pump Version
AMBIENT TEMPERATURE ON CONDENSER (°C)
-7 -5 0 4 7 10 15 20
MODEL
LEAVIGN WATER
TEMPERATURE(żC)
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
HEAT
CAP.
kW
POWER
INPUT
kW
35
6.87 2.25 7.36 2.40 7.81 2.58 9.44 2.72 10.16 2.84 10.66 3.09 11.58 3.30 12.40 3.52
40
6.42 2.34 6.90 2.52 7.40 2.69 8.99 2.82 9.60 2.98 10.25 3.23 11.21 3.45 12.04 3.73
45
6.0 2.46 6.53 2.63 7.07 2.80 8.50 2.94 9.38 3.09 9.90 3.37 10.68 3.58 11.53 3.87
50
6.8 2.91 8.06 2.99 8.70 3.24 9.58 3.53 10.24 3.72 10.99 4.03
MAC040AR
55
6.52 3.01 7.52 3.13 8.27 3.45 9.25 3.69 9.64 3.93 10.54 4.44
35
8.54 2.96 9.12 3.04 10.39 3.22 12.73 3.51 14.70 3.72 16.70 3.93 18.88 4.15 19.84 4.35
40
7.62 3.08 8.13 3.17 9.18 3.43 11.40 3.67 13.61 3.89 15.52 4.11 17.93 4.34 18.76 4.60
45
6.75 3.17 7.4 3.32 8.13 3.64 10.60 3.84 12.60 4.05 14.60 4.24 16.76 4.53 17.37 4.78
50
7.38 3.85 9.75 3.99 11.53 4.19 13.68 4.41 15.91 4.67 16.42 4.92
MAC050AR
55
7.34 4.06 9.06 4.18 10.36 4.36 12.79 4.60 14.84 4.89 15.47 5.09
35 11.01
3.43 12.28 3.52 13.74 3.67 15.50 3.81 16.96 3.88 18.10 4.00 19.87 4.11 21.02 4.78
40
9.64 3.82 10.83 3.95 12.58 4.13 14.30 4.28 15.69 4.32 16.91 4.48 18.72 4.60 19.85 5.17
45
7.88 4.07 9.09 4.48 11.45 4.63 13.16 4.76 14.65 4.85 15.73 4.94 17.87 5.09 18.40 5.68
50
11.0 5.11 12.38 5.18 13.25 5.31 14.50 5.44 17.23 5.58 17.97 6.14
MAC058AR
55
10.15 5.59 11.29 5.62 12.14 5.78 13.31 5.91 16.58 6.07 17.08 6.29
21