Trouble Shooting
When entering fault mode, the display will flash the LED lights to indicate the fault code. This will be indicated
by:
2 long flashes of 2 seconds followed by a sequence of flashes with a 0.5 second interval. The number of quick
flashes indicates the fault code on the table below.
flashes of LED
Cause of trouble
Termination of the third time of combustion
Power voltage out of specified range
Combustion chamber temperature too high during self-check period
Broken circuit or short-circuit of temperature sensor
Broken circuit or short-circuit of fuel pump
Broken circuit, short-circuit, or rotation clogging of fan motor
Broken circuit or short-circuit of glow plug
10
Ambient temperature over high before starting or furnace body temperature over
high during heating process
Broken circuit or short-circuit of overheating sensor
Broken circuit or short-circuit of control switch
Maintenance reminder: More than 800 hours of work time