a) Preparing for decalcication
For safety reasons, once the decalcication process has started it must not be stopped until the system has
been rinsed (see process f). All operating modes of the appliance are blocked until decalcication has been
completed.
Tasks within the RV
Set the control panel to “Off”.
Turn OFF the water supply or switch OFF the water pump.
Open a hot water faucet to relieve pressure in the system.
On all water faucets attach the warning sign “Caution decalcication in progress” in a clearly visible position
Warning signs are enclosed with the decalcication tablets.
b) Draining the water system
Tasks outside the RV
Remove the access door (refer to “Removing the access door” on page 48).
Switch OFF the appliance at the POWER switch.
Drain the water system and remove the water inlet lter. To do this, refer to “Draining the water and cleaning
the water inlet lter” on page 56, Steps 4 to 8.
You must use the water inlet lter for decalcication (included with the delivery
Fig. 1 – 11a). If you are using an electric antifreeze kit, it must be removed and be
unplugged from the power supply before decalcication (see Fig. 11).
NOTICE

Table of Contents