TIMER CONTROL
The ATMe program implements a ON/OFF Cycle Timer, defined with the
Timer parameters (Timer Menu).
When the TIMER mode is activated, the clock is always preceded by the
symbol '-'.
When the ATMe is configured in «TIMER» mode («MODE
TIMER»), the generator is automatically
switching to «UNIT ON» mode when the ATMe is powered ON.
When the generator reaches READY state, the TIMER starts with the following parameters
- HAZE emission during « ON (MIN) » delay, with an output defined by «TIMER
SET PRES»,
- No HAZE emission during « OFF (MIN)» delay.
Then the cycle is repeated indefinitely if «TIMER
END (MIN) = 0 ».
If the « END (MIN) » delay is not at Zero, the generator is automatically switched to «UNIT OFF» mode
when this delay is achieved.
When the TIMER is running, it is possible to disable the TIMER at any time.
When the TIMER is disabled, all TIMER counters are paused, and the generator will stop emitting HAZE if
the generator was in a CYCLE ON phase, proceeding to a purge. When the TIMER is re-enabled, the TIMER
sequence will be resumed.
When the TIMER is DISABLED, the symbol ‘-‘, before the clock, is blinking.
«TIMER
ENABLE = OFF» can be used to force the generator to be purged before switching it, if the END
TIME is not achieved or if the generator is still hazing.