MDS 05-3316A01, Rev. E MDS 4710B/9710B I/O Guide 27
ucts equipped with a 9600 bps modem. When 9600B is selected, the BAUD
command is automatically set to 9600 bps.
OWM [XXX...]
This is a command to display or program an owner’s message. To pro-
gram the owner’s message, type
OWM then the message, followed by
.
To display the owner’s message, type
OWM then . The owner’s
message appears on the display.
OWN [XXX...]
This is a command to display or program an owner’s name. To program
the owner’s name, type
OWN then the name, followed by .
To display the owner’s name, type
OWN then . The owner’s
name appears on the display.
PTT [0–255]
This command sets or displays the key-up delay in milliseconds.
This timer specifies how long to wait after the radio receives a key signal
from either the PTT or RTS lines (on the Data Interface), before actually
keying the radio.
PWR [20–37]
This command displays or sets the desired RF forward output power set-
ting of the radio. The
PWR command parameter is specified in dBm and
can range from 20 through 37. The default setting is 37 dBm (5 watts).
To read the actual (measured) power output of the radio, use the
SHOW
PWR
command. A dBm-to-watts conversion chart is provided in Section
7.5.
RMIS
This local maintenance command initializes the current settings to the
midpoint or 50% for the following local maintenance settings.
• Power
• Frequency
RMOV
This command restores the old values (after the last
RMST command) for
the following remote maintenance settings.
• Power
• Frequency