DC32D GENSET CONTROLLER USER MANUAL
30
Check the genset AC voltage;
Check DC fuse.
High temperature alarm
Check temperature sensor and its wiring.
Check the temperature sensor type and controller settings
must be consistent;
Check whether the temperature sensor is normal.
Shutdown Alarm in
running
Check related switch and its connections according to the
information on LCD; Check programmable inputs.
Fail to start
Check fuel return circuit and wiring.
Check start battery.
Consult engine manual.
Starter motor does not
respond
Check the wiring to the starter.
Check start battery.
USB communication is
abnormal
Check the USB connection;
Check whether the USB port of the computer is normal.
Check whether the USB driver is installed.