Do you have a question about the Megger MIT330 and is the answer not in the manual?
Essential safety warnings and precautions to be observed before and during instrument use.
Description of controls and connections on the instrument's front panel.
Details on connecting test leads to the MIT300 series instruments.
Procedures for checking batteries and test leads before instrument use.
Guidance on voltage warnings and the test lock function for safe operation.
Proper connection of test leads and instrument application guidelines.
Steps to zero out test lead resistance for accurate continuity readings.
Guide to conducting continuity measurements on the instrument.
Safety precautions and automatic discharge for insulation tests.
Step-by-step guide for conducting an insulation test.
Steps for measuring AC and DC voltages with the instrument.
Performing continuity tests and using the continuity buzzer on the MIT310A.
Step-by-step guide for safely replacing the instrument's batteries.
Safety standards, power supply details, and battery longevity.
Guidelines for instrument care, repair, and warranty terms.
Essential safety warnings and precautions to be observed before and during instrument use.
Description of controls and connections on the instrument's front panel.
Details on connecting test leads to the MIT300 series instruments.
Procedures for checking batteries and test leads before instrument use.
Guidance on voltage warnings and the test lock function for safe operation.
Proper connection of test leads and instrument application guidelines.
Steps to zero out test lead resistance for accurate continuity readings.
Guide to conducting continuity measurements on the instrument.
Safety precautions and automatic discharge for insulation tests.
Step-by-step guide for conducting an insulation test.
Steps for measuring AC and DC voltages with the instrument.
Performing continuity tests and using the continuity buzzer on the MIT310A.
Step-by-step guide for safely replacing the instrument's batteries.
Safety standards, power supply details, and battery longevity.
Guidelines for instrument care, repair, and warranty terms.
| Insulation Resistance Range | 0.01 MΩ to 10 GΩ |
|---|---|
| Continuity Test Current | 200 mA |
| Continuity Resolution | 0.01 Ω |
| Voltage Range | 0 to 600 V AC/DC |
| Safety Rating | CAT IV 600 V |
| Operating Temperature | -10 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Insulation Resistance Test Voltage | 250 V, 500 V, 1000 V |
| Display | LCD |
| Weight | approximately 1.2 kg |
| Battery Type | 6 x AA |