MEITRACK T711L GPS Vehicle Tracker User Guide
Copyright © Meitrack Group 2021. All rights reserved. - 14 -
Z2: indicates the detection time of the harsh braking alert. Unit: second. The parameter value ranges from 1 to 255.
If you want to read the command settings, send 0000,BBD.
Example:
SMS sending: 0000,BBD,200,100,10,200,-100,10
SMS reply: 353358017784062,BBD,OK
6.5.6 Setting the Sharp Left Turn or Sharp Right Turn Alert – BC6
SMS sending: 0000,BC6,A,B,C
SMS reply: IMEI,BC6,OK/<Error code>
Description:
A: indicates the angle. The parameter value ranges from 0 to 359.
B: indicates the consecutive cornering time. The parameter value ranges from 2 to 100. Unit: second.
C: indicates the driving speed. The parameter value ranges from 0 to 255. Unit: km/h.
If you want to read the command settings, send 0000,BC6.
Example:
SMS sending: 0000,BC6,90,10,60
SMS reply: 353358017784062,BC6,OK
6.5.7 Controlling Output Status – C01
SMS sending: 0000,C01,Speed,ABCDE
SMS reply: IMEI,C01,OK
Description:
Speed = 0: No speed limit exists. When the device receives the command, the function takes effect immediately.
Speed = [1...255]: Set the speed limit. Unit: km/h. When the driving speed is lower than the speed limit, the function
takes effect.
ABCDE: indicate outputs 1–5 respectively. When the parameter value is 0, the output is disabled. When the parameter
value is 1, data is generated according to the preset output mode. When the parameter value is 2, the previous status
remains unchanged.
Example:
SMS sending: 0000,C01,10,10000
SMS reply: 353358017784062,C01,OK
6.5.8 Setting I/O Port Status – C08
SMS sending: 0000,C08,IO0:Mn,IO1:Mn,IO2:Mn,IO3:Mn,IO4:Mn
SMS reply: IMEI,C08,IO0:Mn,IO1:Mn,IO2:Mn,IO3:Mn,IO4:Mn
Description:
1. IO0, IO1, IO2, and IO3 indicate I/O ports.
IO0: open collector 1 by default (yellow cable: output 1)
IO1: 1-Wire port by default (green cable)
IO2: positive input 1 by default (white cable)
IO3: analog input 1 by default (blue cable)
2. Mn indicates the I/O port status. The parameter value is as follows:
0: low trigger