- 15 -
data=0, to turn off this function;
data=1~65535, set interval for heartbeat.
Example:
W000000,015,10
In this example, the tracker will send heartbeat every 10 minutes.
15. Get IMEI
Command: W******,601
Description: Get IMEI of the tracker. IMEI is 15 digits
Example: W000000,601
16. Initialization
Command: W******,990,099###
Description: This sets all settings, except for the password, back to factory default.
Note: Send SMS Default?” to the device. Within 120 seconds, send this SMS command to the tracker.
### is the ending character and is required in the text message.
Example: W000000,990,099###
17. Password Initialization
Command: W888888,999,666
Description: This resets the password back to factory default and can be used in case you forget your
password.
Note: Send SMS Default? to the device, and then, within 120 seconds, send this SMS command to the
tracker to set the password back to factory default (000000).
If you have set an authorized telephone number, when the password has been successfully preset, the
telephone will receive W888888,999,666
Example: W888888,999,666
For more details regarding SMS commands, please go to Annex 1 Command List.
18. Parameter Editor
The tracker can also be configured by computer using the Parameter Editor. This method is much easier and
user friendly.