MAINTENANCE
32
Inspection And Maintenance Schedule
BEFORE EACH USE
Visually inspect the fuel system for deterioration or leaks.
Check outboard for tightness on transom.
Check steering system for binding or loose components.
Check propeller blades for damage.
AFTER EACH USE
Flush out the outboard cooling system if operating in salt or polluted water. See Flushing the Cooling System.
Wash off all salt deposits with fresh water if operating in salt water.
EVERY 100 HOURS OF USE OR ONCE YEARLY, WHICHEVER OCCURS FIRST
Lubricate all lubrication points. Lubricate more frequently when used in saltwater. See Lubrication Points.
Replace spark plug at first 100 hours or first year. After that, inspect spark plug every 100 hours or once
yearly. Replace spark plug as needed. See Spark Plug Inspection and Replacement.
Drain and replace gearcase lubricant. See Gearcase Lubrication.
Check carburetor adjustments. See Carburetor Adjustment.
Check fuel line filter for contaminants. See Fuel System.
Check corrosion control anode. Check more frequently when used in salt water. See Corrosion Control
Anode.
Lubricate splines on the driveshaft.
1.
Replace water pump impeller.
1.
Check tightness of bolts, nuts, and other fasteners.
BEFORE PERIODS OF STORAGE
Refer to Storage procedure. See Storage section.
Flushing The Cooling System
Flush the internal water passages of the outboard with fresh water after each use in salt, polluted, or muddy water.
This will help prevent a buildup of deposits from clogging the internal water passages.
Use a Mercury Precision or Quicksilver accessory (or equivalent) flushing attachment.
NOTE: Do not run the engine while flushing the cooling system.
1. Remove plug and gasket and thread in hose coupling.
2. Attach a water hose to the hose coupling. Turn on the water gently and flush the cooling system for 3 to 5
minutes.
3. Remove the thread in hose coupling and reinstall plug and gasket.
1.
These items should be serviced by an authorized dealer.