Section 1 - Getting to Know the Axius System
CMD-4082082 / 90-8M0052072 eng FEBRUARY 2011 Page 11
b. Adjust to the desired tension.
Side cover removed
a - Detent tension adjustment screw
b - Handle tension adjustment screw
9. Remove the screw, washer, and handle when the adjustments are complete.
10. Install the side cover. Secure the cover with the three M5 x 10 mm long screws. Tighten the screws to specification.
Description Nm lb‑in. lb‑ft
Side cover screws 3.4 30
11. Apply adhesive to the threads of the handle screw.
Tube Ref No. Description Where Used Part No.
7
Loctite 271 Threadlocker Threads of handle screw 92-809819
12. Install the washer and the M8 x 45 mm long screw. Tighten the screw to specification.
41350
Location of handle screw and washer
Description Nm lb‑in. lb‑ft
Handle screw 28.2 21