Section 1 - Getting to Know the Axius System
CMD-4082082 / 90-8M0052072   eng  FEBRUARY  2011 Page  11
b. Adjust to the desired tension.
Side cover removed
a - Detent tension adjustment screw
b - Handle tension adjustment screw
9. Remove the screw, washer, and handle when the adjustments are complete.
10. Install the side cover. Secure the cover with the three M5 x 10 mm long screws. Tighten the screws to specification.
Description Nm lb‑in. lb‑ft
Side cover screws 3.4 30 –
11. Apply adhesive to the threads of the handle screw.
Tube Ref No. Description Where Used Part No.
7
Loctite 271 Threadlocker Threads of handle screw 92-809819
12. Install the washer and the M8 x 45 mm long screw. Tighten the screw to specification.
Location of handle screw and washer
Description Nm lb‑in. lb‑ft
Handle screw 28.2 – 21