Section 6 - Storage
Page 104 90-899883179 OCTOBER 2007
3. On models with a seawater pickup pump, remove the two blue drain plugs. If the
seawater pickup pump does not have blue drain plugs, or you are unable to access
them, loosen the clamps and remove both hoses.
6145
b
a
a - Hose clamps b - Blue drain plugs
4. Crank the engine over slightly with the starter motor to purge any water trapped in the
seawater pickup pump. Do not allow the engine to start.
5. Before launching the boat or starting the engine, close the drain system by installing
the blue drain plugs.
6. Open the seacock, if equipped, or unplug and reconnect the water inlet hose before
operating the engine.
Draining the Sterndrive
NOTE: This procedure is needed only for salty, brackish, mineral laden, or polluted water
applications; and for freezing temperatures or extended storage.
1. Insert a small wire repeatedly to make sure that vent holes, water drain holes, and
passages are unobstructed and open.
b
a
d
e
f
c
6146
Sterndrive Water Drain Holes
a - Speedometer pitot tube
b - Trim tab cavity vent hole
c - Trim tab cavity drain passage
d - Gear housing water drain hole (one
each at port and starboard)
e - Gear housing cavity vent hole
f - Gear housing cavity drain hole