MAPR_TPS2Rationality
Fault Type: Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 405‑6 Yes 2
Explanation
The values received from the manifold absolute pressure (MAP) sensor and the secondary encoder in the throttle position
sensor (TPS) do not agree.
Possible Causes
MAP or ETC wiring problem
ETC opening is restricted or airflow to the engine is restricted
Intake manifold has vacuum leak
MAP sensor or ETC is failed
Summary of Fault Correction Possibilities
Correct the MAP sensor or ETC wiring problem.
Inspect the cold air intake assembly for obstructions.
Inspect the intake manifold for air leaks.
Replace the MAP sensor or throttle body assembly.
MicroChi_PWM_ADC
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Critical 5% 4003‑6 Yes 4
Explanation
There is a communication problem with the SmartCraft control system.
Possible Causes
Wiring problem
Clean power issue
Failed command module
Summary of Fault Correction Possibilities
Inspect the helm wiring.
Inspect the clean power harness.
Replace the command module.
N ..........
Neutral_Overspeed
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky None 100% 2092‑23 No 1
Explanation
Engine speed is above specified limits with the engine in neutral.
Possible Causes
Engine is not in gear
Shift demand sensor failed
Summary of Fault Correction Possibilities
Shift the engine into gear.
Inspect the shift demand sensor.