TPS1_RangeHigh
Fault Type: Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Sticky Caution 100% 301‑24 Yes 2
Explanation
The TPS 1 sensor circuit is shorted.
Possible Causes
Wiring problem
Defective throttle position sensor
Summary of Fault Correction Possibilities
Inspect the wiring for problems, and correct as necessary.
Replace the throttle body assembly.
TPS1_RangeLow
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Sticky Caution 100% 301‑25 Yes 2
Explanation
The TPS 1 sensor circuit is open.
Possible Causes
Wiring problem
Defective throttle position sensor
Summary of Fault Correction Possibilities
Inspect the wiring for problems, and correct as necessary.
Replace the throttle body assembly.
TPS2_ETC_NoAdapt
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Nonsticky Caution 100% 342‑6 Yes 2
Explanation
The TPS 2 signal was outside the valid range when trying to adapt. Adapt occurs upon engine key‑up.
Possible Causes
Wiring problem
Defective throttle position sensor
Summary of Fault Correction Possibilities
Inspect the wiring for problems, and correct as necessary.
Replace the throttle body assembly.
TPS2_RangeHigh
Fault Type:
Horn: Guardian: UFC: Transmission to Helm: Freeze Frame Priority:
Sticky Caution 100% 302‑24 Yes 2
Explanation
The TPS 2 sensor circuit is open.
Fault Codes