4-8 Revised 06.2021
Owner’s Manual: Smoothwall Bin
®
Fig 21 - Horizontal AirMax™ Aeration tube
Fig 23 - Vertical Aeration
-One-Piece
Fig 24 - Vertical Aeration
-Sectional
Fig 22 - AirMax™ In-Line fan
Fig 25 - AirMax™ Centrifugal fan
4.3 MERIDIAN AIRMAX® AERATION SYSTEMS
One of these Airmax™ Aeration systems may
have come with your bin to condition the product
stored inside.
CORROSIVE MATERIAL HAZARD
Do not store fertilizer in a bin
containing an aeration system.
4.3.1 Airmax Horizontal Aeration System:
The horizontal aeration tube is inserted through
the fan mount. Then the fan can be installed.
Bolt the in-line fan to the mount in a way that
the electrical lines can be routed conveniently.
The aeration tube is removable, to facilitate
cleaning of the screen.
Remove the fan, then unfasten the bolts and
carefully pull the tube out of the bin.
Once the tube is removed, replace the cover
plate to prevent moisture and pests from
entering the bin.
Horizontal Aeration Disclaimer:
Remove the horizontal aeration tube if
fertilizer will be stored in the bin. If left
inside, it could limit or void the warranty if
the cause of a claim is deemed to be from
the storage of fertilizer.
4.3.2 Airmax Vertical Aeration System:
The internally mounted “rocket” has a hollow
duct design formed by a self-cleaning perforated
metal screen.
Bolt the centrifugal fan to the mount on the
hopper bottom.