17.9.2007 Rev. 2.4
Troubleshooting
14
6. Troubleshooting
Should the appliance fail to produce ice, before calling on the Authorized Technical Serv-
ice Centre, first check carefully that:
The water supply tap provided in the istallation phase is open.
The electric power is reaching the appliance, the plug is properly inserted, and the
power switch is in the “on” position.
In the event of excessive noise, check that the appliance does not come into contact
to next fixtures, that may cause noise or vibrations.
Should any traces of water appear, check that the discharge hole of the container
is not obstructed, that the water feed and discharge pipes are correctly installed up
and do not present any throttling or damage.
Make sure that the temperature of the air or water does not exceed the installation
limit values.
Make sure that the water inlet filter is not clogged.
Make sure that the spray nozzles are not clogged with scaly deposits.
Once the above checks have been made, if the appliance were still to present malfunction-
ing, switch off the power supply, pull out the plug from its socket, close the water tap
connecting the appliance up to the water supply, and call the nearest Authorized Technical
Service Center.
In order to obtain a faster and more efficient intervention, when you call the Center, indi-
cate the model of the apparatus precisely, and its serial number. These can be read on the
matriculation lable stuck on the rear of the appliance or on the cover of this manual.
MALFUNCTION Possible cause Operation
Ic -cube maker does not function Appliance does not function Check power supply
Thermostat in the container does not
func.
Change the thermostat
Safety thermostat of the condenser does
not function.
Change the thermostat
Safety pressure switch has cut off (C300) Settle the pressure switch
Contactor does not function/burned down Change contactor
Appliance functions, but does not
make proper ice
There is no coolant gas Find leakage, fix it, vacuumize and fill
up
Warm gas valve leaks Fix or change the valve
Compressor does not pump Change the compressor
Air condensed models Check the fan, change if needed
Condenser fan does not function Check the function. of the pressure
switch
Water basin receives no water Solenoid valve does not open or is
blocked
Change the valve
Slide pulse does not open the valve Change the slide pulse