Double Acting Actuators:
A. Back o one travel stop screw, leaving it partially
threaded in the end cap. Entirely remove the other
stop screw from the other end cap.
B. Open valve using air pressure. NOTE: Actuator will
leak due to removed travel stop.
C. Use the indicator pointer on top of actuator to
determine if valve is open to desired position. If not,
repeat steps 1-3, backing o or screwing in stop
screw to attain proper open position of valve.
D. Make sure O-ring is in proper position in countersunk
area on end cap and the washer is in place. Tighten
down nut to set stop position.
E. Thread in the other travel stop, making sure the
O-ring and washer are in the correct place. When the
travel stop will not thread any further, tighten nut to
set stop position.
F. The previous steps set the open travel stop. See
section 4.3.5 for instructions on setting the close
position stop.
Spring Return Actuators:
A. Back o one travel stop screw, leaving it partially
threaded in the end cap. Entirely remove the other
stop screw from the other end cap.
B. Open valve using air pressure. Note actuator will leak
due to removed travel stop.
C. Keeping air pressure applied to actuator, use the
indicator pointer on top of actuator to determine if
valve is open to desired position. If not, remove air
pressure and repeat steps 1-3, backing o or screwing
in stop screw to attain proper open position of valve.
D. Make sure O-ring is in proper position in countersunk
area on end cap and the washer is in place. Tighten
down nut to set stop position.
E. Thread in the other travel stop, making sure the
Oring and washer are in the correct place. When the
travel stop will not thread any further, tighten nut to
set stop position.
F. The previous steps set the open travel stop. See
section 4.3.5 for instructions on setting the close
position stop.
5. SAFETY LOCKOUT DEVICE
WARNING:
IF THE SERIAL NUMBER OF THE ACTUATOR IS 10136023 OR LOWER
THEN THE ACTUATOR MUST BE DISASSEMBLED AND THE OCTICAM
1 MUST BE ROTATED, SEE FIGURE 9, BEFORE INSTALLING THE
SAFETY LOCKOUT KIT.
Figure 19

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metso Jamesbury Valv-Powr Value-Line D VPVL Series and is the answer not in the manual?

Metso Jamesbury Valv-Powr Value-Line D VPVL Series Specifications

General IconGeneral
BrandMetso
ModelJamesbury Valv-Powr Value-Line D VPVL Series
CategoryController
LanguageEnglish

Related product manuals