MFJ-464 Instruction Manual CW Keyer/Reader
40
Appendices
Resetting the Keyer
Each time the keyer is turned off, the microprocessor powers down and saves all memories and
configurations to non-volatile memory ready to be used the next time the unit is turned on again.
If the keyer in not working properly, even on initial power on, try resetting to the factory
defaults.
Factory Defaults
The unit is shipped with the following default settings:
Main Menu Speed
Setup Menu Overall Speed
Quick Menu Keyboard Layout
Overall Speed 13 WPM
Farnsworth off
Weight 50%
Character Space 3 units
Word Space 7 units
Keying Compensation 0 msec
Keying Delay 0 msec
PTT Hang Time 1000 msec
Tone Frequency 701 Hz
Serial Number 0001
Leading Zeroes on and send as O (dah-dah-dah)
Other Zeroes send as 0 (dah-dah-dah-dah-dah)
Nines send as 9 (dah-dah-dah-dah-dit)
Iambic Mode A
Reverse Mode off (dot to tip, dash to ring)
Paddle Mode automatic
Monitor Mode on
Output Mode on
Queue Mode on
Pulse Tune Speed 75 WPM
Pulse Tune Weight 13% duty cycle
Quick Speeds 13, 15, 18 and 20 WPM
Keyboard Layout Qwerty keyboard
Repeat Key off
Caps Lock on
To reset the keyer to these defaults: