Page 5
General
capaNCDT 6220/6222/6230
Proper Environment
Temperature range controller
Operation Storage
+10 ... +60 °C (+50 ... +140 °F) -10 ... +75 °C (+14 ... +167 °F)
Temperature range sensor Operation Storage
CS005, CS02, CS05, CS08,
CS1, CS2, CS3, CS5, CS10
-50 ... +200 °C
(-58 ... +392 °F)
-50 ... +200 °C
(-58 ... +392 °F)
CSH02, CSH05, CSH1, CSH1.2, CSH2
CSH02FL, CSH05FL, CSH1FL,
CSH1.2FL, CSH2FL, CSH3FL
CSE01, CSE05, CSE025, CSE1, CSE2
CS1HP
CSG0.50, CSG1.00
-50 ... +100 °C (-58 ... +212 °F) -50 ... +100 °C (-58 ... +212 °F)
Temperature range sensor cable Operation Storage
Up to 10,000 operating hours Permanent
CCgxC, CCgxC/90
-20 ... +100 °C (-4 ... +212 °F)
-20 ... +80 °C
(-4 ... +176 °F)
-50 ... +80 °C
(-58 ... +176 °F)
CCgxB , CCgxB/90
CCmxC, CCmxC/90
-100 ... +200 °C
(-148 ... +392 °F)
-50 ... +200 °C
(-58 ... +392 °F)
CCmxB, CCmxB/90
Protection class IP40
Humidity 5 ... 95 % (non-condensing)
Ambient pressure Atmospheric pressure