EasyManua.ls Logo

MICRO-EPSILON optoNCDT ILR 102 series - Page 40

MICRO-EPSILON optoNCDT ILR 102 series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 40
Operation
optoNCDT ILR 102x/110x/115x
Command Name Data to
ILRxx
Data from ILR11xx Specification
„IH1“ input
hysteresis Q1
„000“.. „254“
respectively
0“..“999“
(INCH)
ACK Hysteresis setting around the switching points Q1 in
[mm] or [INCH * 100]
„IH2“ input
hysteresis Q2
„000“.. „254“
respectively
00“..“999“
(INCH)
ACK Hysteresis setting around the switching points Q2 in
[mm] or [INCH * 100]
„IL1“ input limit
Q1 1
Offset ...
+12000+Off-
set respec-
tively Offset ..
48000+Off-
set
ACK Setting of the first switching point Q1 in [mm] or
[INCH * 100]
„IL2“ input limit
Q2 1
Offset ...
+12000+Off-
set bzw
Offset ..
48000+Off-
set
ACK Setting of the first switching point Q2 in [mm] or
[INCH * 100]
„IL3“ input limit Q
analog 1
Offset ...
+12000+Off-
set bzw
Offset ..
48000+Off-
set
ACK ILR11x0 only:
Setting of the 0 % point of the analog characteristic,
see Chap. 6.2.5

Related product manuals