If your pump has not included the enable option then it will not be possible to access the “Enable” submenu and the
flashing message "DEA" will appear:
BROKEN HOSE (OPTIONAL)
What is that?
It is a sensor that detects if the peristaltic tube is torn and leaves the chemical to
come out.
When the broken hose alarm starts, it stops the dosage and the green led flashes
and the display shows “broken hose”.
Before any intervention, disconnect the pump from the mains supply!
During the operation always use the personal protections recommended
by the warnings of use of the dosed chemical. For example, use gloves,
apron, glasses, etc ...
The peristaltic hose must therefore be changed. The sensor area inside the pump housing must also be rinsed and
carefully dried. See the explanatory image above.
To esc from this alarm push the ESC button.
Once the operation has been carried out safely, the pump can be restarted.
NB: IF THE PUMP IS SWITCHED OFF DURING THE BROKEN HOSE ALARM, WHEN IT WILL BE SWITCHED ON
AGAIN IT WILL REMEMBER THE PREVIOUS ALARM. TO EXIT FROM THE BROKEN HOSE ALARM SHORTLY
PUSH THE ESC BUTTON.
In the case that your pump has the “Broken Hose” option, you can choose to activate this input or not.
In the Set up menu, select "Brok.Hose" by the cursor and
press ENTER.
Use the buttons to select whether to enable (“active”)
or disable (deactivate) this input and press ENTER.
If you want to esc programming and return to
measurement, press ESC for 3 seconds
If your pump has not the Broken Hose option then it will not be possible to access the “Brok.Hose” submenu and the
flashing message "DEA" will appear:
DATE AND HOUR
The correct definition of the date and time are fundamental for the Quantity, Timer Dos and Timer dosage.
NB: the date and hour are not reset with the pump Reset (Utility menu)
In the Set up menu, select "Date - Hour" by the cursor and
press ENTER.
Use the buttons to set the date in the format dd/mm/yyyy
and the time hh:mm:ss and press ENTER.
If you want to esc programming and return to measurement,
press ESC for 3 seconds

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MICRODOS MP2-HT MF and is the answer not in the manual?

MICRODOS MP2-HT MF Specifications

General IconGeneral
BrandMICRODOS
ModelMP2-HT MF
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals