As soon as the container is empty, press ENTER to
stop the pump dosing.
The pump calculates the flowrate and writes it. Press
ENTER to confirm it.
If the display shows "Flowrate Error" message repeat
the calibration by increasing or decreasing the quantity
of product.
If you want to esc programming and return to
measurement, press ESC for 3 seconds.
MENU UTILITY
The Utility menu allows you to program the Delay On and to restore the factory programming of the parameters.
Press the ENTER/MENU button for 3 seconds to enter
programming.
Select by the cursor the menu Utility and press ENTER.
Use the ▼▲ buttons to move the cursor to the submenus.
Press ENTER to enter the submenu.
If you want to esc programming and return to measurement,
press the ESC button for 3 seconds.
DELAY ON
WHAT IS IT? The Delay On is the time in minutes (from 0-99minutes) that the pump waits after its power on to dose the
chemical. During this time, the display shows the message "Delay On" that alternates with the writing of the operating
mode and the flow rate. During this time, the pump cannot dose but it is possible to program parameters and calibrations.
NB: the Delay On has no effect on the TIMER dosing mode.
HOW TO PROGRAMM THE DELAY ON:
In the Utility menu, select "Delay On" by the cursor and press
ENTER.
Use the ▼ ▲ buttons to select the desired minutes of delay
and press ENTER.
Attention: the change will be active from the next power
on of the pump!
If you want to esc programming and return to measurement,
press ESC for 3 seconds.
RESET PROGRAMMING PARAMETERS
Attention: the Reset has no influence on the Calibration of the flowrate, Date and hour, Language, Password
In the Utility Menu, select "Reset" by the cursor and press
ENTER.
Use the ▼ ▲ keys to display "Yes" on Confirm. Press
ENTER.
Automatically the pump restores the factory settings.
Press the ESC button for 3 seconds to exit programming.