EXAMPLE OF MODIFICATION OF mL Tot.:
In the menu Dosing, select by the cursor "Timer
Dos" and press ENTER.
In the figure on the left you can see the factory
parameters.
Use the ▼▲ buttons to select the parameter to be
changed and press ENTER.
Use the ▼▲ buttons to select the desired value and
press ENTER whenever necessary to confirm the
change.
If you want to esc programming and return to
measurement, press the ESC button for 3 seconds.
PARAMETER:
mL Tot: total amount of chemical to be dosed in one day
Total hours: total number of hours during which the pump has to dose
M T W T F S S : Monday; Tuesday; Wednesday; Thursday; Friday; Saturday; Sunday the "x" enables dosing
x x x x x x x
The hours count starts from the first daily switching on of the pump (if the pump does not have the enable) or
from the first daily reception of the Enable signal (if the pump has the optional of Enable and if this is active in
the Set Up menu).
TIMER DOSING
This type of dosing is timed..
The pump has a clock to set in Set up, page 23.
There are 10 daily dosing schedules that can be repeated or not on different days of the week.
EXAMPLE OF MODIFICATION OF mL Dos:
EXAMPLE OF MODIFICATION OF WEEK DAYS:
In the menu Dosing, select by the cursor "Timer" and
press ENTER.
No timer dosage is programmed at the factory.
NB: To program the Timer dosing, select
the program 1 with the cursor, press
ENTER and write "On" with the ▼▲
buttons and confirm with ENTER.
Then proceed to select the start time of the dosage,
the ml to be dosed (mL Dos), the flow rate of dosing
(% Flowrate) and finally the days of the week during
which the pump has to dose. The "x" enables dosing.
Use the ▼▲ buttons to select the parameter to be
changed and press ENTER.
Use the ▼▲ buttons to select the desired value and
press ENTER whenever necessary to confirm the
change.
If you want to esc programming and return to
measurement, press the ESC button for 3 seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MICRODOS MP2-HT MF and is the answer not in the manual?

MICRODOS MP2-HT MF Specifications

General IconGeneral
BrandMICRODOS
ModelMP2-HT MF
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals