The Keypad
The Scorpion Z4120C, Z6020C and Z8020C communicate system status through the keypad beeper. During
an arming cycle the beeper will sound for the entire exit time. This is a ‘leave now’ warning. Scorpion will
arm at the expiry of this period. On entry, the beeper sounds for the programmed entry period. If a valid user
code is entered to disarm the system, the beeper emits two short tones. An incorrect entry is signalled by one
long tone.
The ‘Status’ Lamp
The yellow status lamp is used to indicate several conditions.
Yellow lamp on: the system is armed or arming
Yellow lamp off: the system is disarmed
Yellow lamp flashing: an alarm has occurred, a system fault exists or
the panic function has been activated
The ‘Mains’ Lamp
The ‘Mains’ lamp is on when mains power is applied. In the event of a mains failure the ‘Mains’ light flashes
until mains power is restored, and an arm/disarm cycle is completed. The ‘Mains’ lamp also flashes to indicate
a low battery condition. When the battery is restored to full charge and an arm/disarm cycle is completed, the
‘Mains’ lamp stops flashing.
The ‘Armed’ Lamp
The ‘Armed’ lamp illuminates when the system is armed. The ‘Armed’ lamp also flashes to indicate when an
alarm condition has occurred.