If all zones are clear, the keypad sounds a repeating sequence of three short beeps for the duration of the exit
delay and the yellow status lamp turns on. The zone lamps for all zones that are arming are also turned on. At
the end of the exit delay the zone lamps extinguish and the system is now armed.
If a zone fault or potential alarm condition exists and the user attempts to arm the system, the lamp(s) for those
zone(s) flash and are accompanied by a repeating sequence of two long beeps. This indicates that one or more
of the zones are faulty or not secured. The panel should be disarmed, the problem located (possible open door
or window) and the system re-armed.
To Arm the System and Exclude a Zone(s)
Enter a valid user code then * (all zone led’s light) followed by the zone number(s) to be excluded (those
zone led’s turn off), then press #.
Example: to arm the system with zones 4 and 5 excluded press:
Disarming
the System
Follow the same sequence as for arming, enter a valid two, three or four digit user code then #. To send a
duress signal to a monitoring station while disarming, hold the # key down until a second beep is heard.
The keypad will beep twice and the yellow status light will
turn off. A flashing yellow status lamp indicates that one or more zones have been alarmed. The zone lamps
6

Other manuals for Micron Scorpion Z6020C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Micron Scorpion Z6020C and is the answer not in the manual?

Micron Scorpion Z6020C Specifications

General IconGeneral
BrandMicron
ModelScorpion Z6020C
CategoryNetwork Router
LanguageEnglish

Related product manuals