SA.22c Rubidium Oscillator
Designer Reference and User Guide Revision D 39
7.9.3 Holdover
During holdover, 1PPS input statistics are accumulated and the results are calculated periodically
(CalcSlope State). The sample size is set to 120 data points (120 s).