Proper installation locations meet the following standards:
Enough room exists for
installation and maintenance.
Enough room exists for the
connecting the pipe and drainpipe.
The ceiling is horizontal and its structure can
sustain the weight of the indoor unit.
The air inlet and outlet
are not blocked.
The airflow can fill
the entire room.
DO NOT
install unit in the following locations:
Areas with oil drilling or fracking
Coastal areas with high salt content in the air
Areas with caustic gases in the air, such as
hot springs
Areas that experience power fluctuations, such
as factories
Enclosed spaces, such as cabinets
Kitchens that use natural gas
Areas with strong electromagnetic waves
Areas that store flammable materials or gas
Rooms with high humidity, such as
bathrooms or laundry rooms
Select installation location1
NOTE
There is no direct radiation
from heaters.
10
Models with a cooling capacity of 9000Btu to 18000Btu only apply to one room.
Before installing the indoor unit, you must choose an appropriate location. The following are
standards that will help you choose an appropriate location for the unit.