Do not clean the air conditioner with combustible cleaning agents. Combustible
cleaning agents can cause fire or deformation.
Turn o the device and disconnect the power before cleaning. Failure to do so
can cause electrical shock.
Do not clean the air conditioner with excessive amounts of water.
CLEANING AND MAINTENANCE WARNINGS
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
This air-conditioning unit contains fluorinated greenhouse gasses. For specific
information on the type of gas and the amount, please refer to the relevant label on
the unit itself or the “Owner's Manual - Product Fiche ” in the packaging of the
outdoor unit. (European Union products only).
Installation, service, maintenance and repair of this unit must be performed by a
certified technician.
Product uninstallation and recycling must be performed by a certified technician.
For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes
of CO2 equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the
system has a leak-detection system installed, it must be checked for leaks at least
every 24 months.
When the unit is checked for leaks, proper record-keeping of all checks is strongly
recommended.
WARNING FOR USING R32/R290 REFRIGERANT
Amount of refrigerant
to be charged (kg)
Minimum room area (m)
1.11 1
1.65 2
2.58 5
3.08 7
3.84 10
4.24
Model (Btu/h)
12000
18000
24000
30000
36000
42000-48000
12
4.3955000-60000 13
When flammable refrigerant are employed, appliance shall be stored in a well -
ventilated area where the room size corresponds to the room area as specifiec for
operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger
than X m. Appliance shall not be installed in an unvertilated space, if that space is
smaller than X m (Please see the following form).
Reusable mechanical connectors and flared joints are not allowed indoors.
(EN Standard Requirements).
Mechanical connectors used indoors shall have a rate of not more than 3g/year at
25% of the maximum allowable pressure. When mechanical connectors are reused
indoors, sealing parts shall be renewed. When flared joints are reused indoors, the
flare part shall be re-fabricated. (UL Standard Requirements)
When mechanical connectors are reused indoors, sealing parts shall be renewed.
When flared joints are reused indoors, the flare part shall be re-fabricated. (IEC
Standard Requirements)