EasyManuals Logo

Midea MAD22C1AWS User Manual

Midea MAD22C1AWS
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8
NOTE
When CONTINUOUS mode function is
turned on, set humidity is automatic
and cannot be changed manually.
(FILTER) Button
This feature is a reminder to clean the Air
Filter for more efficient operation. The LED
(light) will after 250 hours of
operation. To reset after cleaning the filter,
press the Filter button and the light will go
off. The 250 hour counter will reset.
(CONTINUE) Button
Press to activate the continuous
dehumidifying operation.
(TURBO) Button
Control the Turbo speed. Press to select
either Turbo or normal fan speed. Set
the Turbo control to high for maximum
moisture removal. When room humidity is
at your preferred level, it is advised to turn
off Turbo speed.
(TIMER) Button
Starts the Timer ON and Timer OFF
function setting.
Up/Down Buttons (
/ )
Humidity Set Control Buttons
The humidity level can be set within a
range of 35% RH (Relative Humidity)
to 85% RH (Relative Humidity) in 5%
increments.
For drier air, press the
button and set
to a lower value (%).
For damper air, press the
button and
set a higher value (%).
TIMER Set Control Buttons
Use the
and key buttons to set
the Timer ON or Timer OFF from 0 to
24 hours.
(POWER) Button
Press to turn the dehumidifier on and off.
LED Display
Shows the set % humidity level from 35%
to 85% or auto start/stop time (0 ~ 24)
while setting, then shows the actual (+/- 5%
accuracy) room % humidity level in a range
of 30% RH (Relative Humidity) to 90% RH
(Relative Humidity).
Error Codes and Protection Code:
AS - Humidity sensor error - Unplug
the unit and plug it back in. If error
persists, contact Customer Service.
ES - Tube Temperature sensor of the
evaporator error - Unplug the unit
and plug it back in. If error persists,
contact Customer Service.
P2 - Bucket is full or bucket is not in right
position - Empty the bucket and
replace it in the right position. (only
available for the unit with no pump
feature.)
P2 - Bucket is full - Empty the bucket.
(only available for the unit with
pump feature.)
EC - Refrigerant leakage detection -
Display area will show EC when th
e
unit detects refrigerant leakage. If
error persists, contact Customer
Service.
Eb - Bucket is removed or not in right
position - Replace the bucket in the
right position. (only available for the
unit with pump feature.)
Operating
Instructions
(COMFORT) Button
Press to activate the comfort dehumidifying
operation.
NOTE
On this operation,the unit can not be set
humidity level. For some models, under
comfort dehumidifying operation, press
Up/Down button will cancel this feature.
flash

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MAD22C1AWS and is the answer not in the manual?

Midea MAD22C1AWS Specifications

General IconGeneral
BrandMidea
ModelMAD22C1AWS
CategoryDehumidifier
LanguageEnglish

Related product manuals