Air-cooled modular chiller unit 50Hz MCAC-ATSM-2011-12
2
Content
1 General information ................................................................................ 3
2. Features ................................................................................................... 5
3. Specification ........................................................................................... 9
4 Dimension .............................................................................................. 21
5 Refrigeration system drawing .............................................................. 33
6. Piping diagram ...................................................................................... 36
7 Wiring diagrams..................................................................................... 42
8 Electric characteristics ......................................................................... 56
9 Capacity tables ...................................................................................... 58
10 Exploded view ...................................................................................... 74
11 Troubleshooting ................................................................................... 96
12 Installation .......................................................................................... 108
13 Commissioning .................................................................................. 132
14 Maintenance ....................................................................................... 135
15 Control system .................................................................................. 137
Appendix ................................................................................................. 174

Questions and Answers

  • M
    Mr. Brandon HendersonSep 8, 2025
    Why is the air side heat exchanger in my Midea MGB-D30W/RN1 excessively frosted?
    • S
      smithmichaelSep 8, 2025
      Excessive frost on the air side heat exchanger can be due to a faulty 4-way valve or thermal resistor (check and replace if needed) or an air loop short-circuit (resolve the short-circuit).
  • K
    Kenneth DoyleSep 10, 2025
    How to fix over low air discharge pressure in Midea MGB-D30W/RN1 (Heating operation)?
    • K
      Kelly HolmesSep 10, 2025
      Low air discharge pressure during heating may be caused by low chilling water temperature (check it) or refrigerant leakage or insufficient refrigerant volume (test for leaks and recharge). If the air suction pressure is too low, see the section on “Excessive low air suction pressure”.
  • A
    Anthony VelasquezSep 12, 2025
    What to do if my Midea MGB-D30W/RN1 compressor can’t start?
    • D
      Donna GillSep 12, 2025
      If the compressor won't start, check for a tripped overcurrent relay or burnt fuse (replace), power to the control circuit (check wiring), high or low voltage protection (refer to air suction and discharge pressure error sections), burnt contactor coils (replace), incorrect phase sequence (reconnect any two of the three phases), water system error or shorted flow-type volume controller (check water system), or error signals from the wire controller (identify and address the error).
  • M
    Meagan JacobsSep 13, 2025
    What to do if my Midea MGB-D30W/RN1 Chiller compressor stops because of integrate temperature sensor or air discharge temperature protection?
    • M
      Mark UnderwoodSep 13, 2025
      If the compressor stops due to the integrated temperature sensor or air discharge temperature protection, check for high or low voltage (ensure it's within 20V of the rated voltage), high air expelling pressure or low air suction pressure (refer to those sections), or a component error (check the integrated temperature sensor after the motor cools down).
  • F
    Fernando HowardSep 15, 2025
    What causes over low air suction pressure in Midea MGB-D30W/RN1 Chiller (Heating operation)?
    • S
      scottbrittneySep 15, 2025
      Low air suction pressure during heating can result from insufficient refrigerant (charge the system), insufficient air flow (check fan direction), an air loop short-circuit (remove the short-circuit), or insufficient frost-removal (replace the 4-way valve or thermal resistor if necessary).
  • C
    Craig GonzalezSep 18, 2025
    What could cause abnormal noise from the compressor in my Midea MGB-D30W/RN1?
    • J
      jjarvisSep 18, 2025
      Abnormal compressor noise can be due to liquid refrigerant entering the compressor from the evaporator, causing liquid slugging (adjust refrigerant charge), or the compressor aging (replace the compressor).

Summary

General Information

Product Schedule

Lists product specifications and capacities.

Features

Modular Design

Explains the flexible modular design and combination capabilities.

Specification

Model and Cooling Capacity

Lists chiller models with their cooling capacity in kW and Btu/h.

Heating Capacity

Details the heating capacity of the chiller units.

Power Supply Details

Specifies voltage, phase, frequency, manual switch, and fuse.

Compressor Specifications

Information on compressor type, quantity, model, brand, capacity, input.

Power Input and Current Ratings

Details cooling and heating power input and current ratings.

Refrigerant and Control

Specifies refrigerant type and control method.

Condenser (Air Side) Specifications

Describes air-side heat exchanger type and fan specifications.

Evaporator (Water Side) Specifications

Details water-side heat exchanger and pipeline specifications.

Unit Dimensions

Provides net and packing dimensions in mm and inch.

Dimension

25;30 KW Module Dimensions

Provides dimensional drawings and data for 25/30KW modules.

55;60;65 KW Module Dimensions

Dimensional drawings and data for 55/60/65KW modules.

130 KW Module Dimensions

Dimensional drawings and data for the 130KW module.

185 KW Module Dimensions

Dimensional drawings and data for the 185KW module.

250 KW Module Dimensions

Dimensional drawings and data for the 250KW module.

Refrigeration System Drawing

Piping Diagram

Wire Diagrams

Chiller Wiring Diagram

General wiring diagram for the chiller unit.

Networking Communication Schematic

Electric Characteristics

Model and Electrical Specifications

Lists chiller models with their electrical characteristics.

Power Supply and Outdoor Unit Parameters

Electrical supply and outdoor unit parameters.

Compressor Electrical Specifications

Details compressor electrical specifications like TOCA, MFA, LRA, RLA, KW, FLA.

Capacity Tables

MGB-F(D)25 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F(D)25W/RN1 model.

MGB-F(D)25 W;RN1 Heating Capacity

Heating capacity data for MGB-F(D)25W/RN1 model.

MGB-F(D)30 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F(D)30W/RN1 model.

MGB-F(D)30 W;RN1 Heating Capacity

Heating capacity data for MGB-F(D)30W/RN1 model.

MGB-F55 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F55W/RN1 model.

MGB-F55 W;RN1 Heating Capacity

Heating capacity data for MGB-F55W/RN1 model.

MGB-F60 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F60W/RN1 model.

MGB-F60 W;RN1 Heating Capacity

Heating capacity data for MGB-F60W/RN1 model.

MGB-F65 W;RN1, MGB-D65 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F65W/RN1 and MGB-D65W/RN1.

MGB-F65 W;RN1, MGB-D65 W;RN1 Heating Capacity

Heating capacity data for MGB-F65W/RN1 and MGB-D65W/RN1.

MGB-F130 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F130W/RN1 model.

MGB-F130 W;RN1 Heating Capacity

Heating capacity data for MGB-F130W/RN1 model.

MGB-F185 W;RN1 Cooling Capacity

Cooling capacity data for MGB-F185W/RN1 model.

MGB-F185 W;RN1 Heating Capacity

Heating capacity data for MGB-F185W/RN1 model.

MGBT-F250 W;RN1 Cooling Capacity

Cooling capacity data for MGBT-F250W/RN1 model.

MGBT-F250 W;RN1 Heating Capacity

Heating capacity data for MGBT-F250W/RN1 model.

Exploded View

Troubleshooting

Failure and Protection Codes of the Module

Lists fault and protection codes for the chiller modules.

Troubles and Solutions

Lists common troubles and their corresponding solutions.

Installation

Unit Installation

General guidelines and procedures for installing the unit.

Water System Installation

Guidelines for installing the water system.

Wiring Installation

Instructions for performing wiring installation.

Wiring Installation Precautions

Safety precautions for wiring installation.

Power Supply Specifications

Detailed power supply specifications for various models.

Wiring Steps

Step-by-step instructions for wiring the unit.

Commissioning

Preparation for Commissioning

Steps for preparing the unit before commissioning.

Test Run Procedures

Procedures for conducting a test run on the unit.

Maintenance

Main Component Maintenance

Routine maintenance procedures for key components.

Refrigeration System Checks

Checks and procedures for the refrigeration system.

Control System

PCB Outline and Description

Overview and description of the main control PCB.

Wired Controller Operation

Midea MGB-D30W/RN1 Specifications

General IconGeneral
BrandMidea
ModelMGB-D30W/RN1
CategoryChiller
LanguageEnglish