Outdoor Unit Disassembly 41
Procedure Illustration
5) Pull out the wire connected with the
terminal. (see CJ_ODU_PCB_007-4).
6) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(TP) (see CJ_ODU_PCB_007-4).
7) Disconnect the electronic expansion
valve wire (see Fig CJ_ODU_PCB_007-
4).
8) Remove the connector for 4-way valve.
(see Fig CJ_ODU_PCB_007-4).
9) Remove the connector for the reactor
(see Fig CJ_ODU_PCB_007-4).
10) Then remove the electronic control box
(see Fig CJ_ODU_PCB_007-4).
CJ_ODU_PCB_007-4
Note: This section is for reference only. Actual unit appearance may vary.
4-Way Valve
Reactor
T3/T4
TP
Terminal