10. Compressor
10.1 Compressor on and off control specifications
1.1 When one of the following conditions is met, the compressor stops:
1) Measured temperature in all chambers Shutdown temperature of all chamber
2) Enter defrosting cycle
3) The compressor runs continuously for more than 3 hours, will stop at least 10 minutes
1.2 When compressor shutdown time has been more than 5 min, one of the following conditions is
met, the compressor starts up:
1) Measured temperature in freezer chamber ≥ Start up temperature of freezer
2) Refrigerator is set to forced cooling mode or super cooling or super freeze mode
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state
Shutdown temperature and Start up temperature have different values due to ambient
temperature.