Service manual
29
Input kW. 1.06 0.93
0.77 0.71 0.65
10.5 MSC-12CRN1
SUMMER OUTDOOR TEMPERATURE DRY
Indoor Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total capacity kW 3.276
21ºC D
15ºC W
Input kW. 0.89 1.01 1.082
24ºC D
17ºC W
Input kW. 0.915
Total capacity kW 3.86 3.7
3.5
3.371
27ºC D
19ºC W
Input kW. 0.944
32ºC D
23ºC W
Input kW. 0.969
10.6 MSC-12HRN1
SUMMER OUTDOOR TEMPERATURE DRY
Indoor
Conditions
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
Total capacity kW 3.276 3.187 3.105 2.821 2.746 2.621
Sensitive capacity kW
2.567 2.457 2.413 2.287 2.21 2.087
21ºC D
15ºC W
Input kW. 0.89 1.01 1.082 1.188 1.243 1.337
Total capacity kW 3.663 3.503 3.315 3.148 3.076 2.932
Sensitive capacity kW 2.918 2.766 2.725 2.557 2.453 2.334
24ºC D
17ºC W
Input kW. 0.915 1.033 1.121 1.228 1.278 1.367
Total capacity kW 3.86 3.7
3.5
3.371 3.215 3.125
Sensitive capacity kW 3.039 2.913
2.832
2.645 2.567 2.419
27ºC D
19ºC W
Input kW. 0.944 1.048
1.1
1.253 1.312 1.426
Total capacity kW 4.215 4.1 3.845 3.601 3.501 3.313
Sensitive capacity kW 3.12 2.939 2.891 2.715 2.589 2.503
32ºC D
23ºC W
Input kW. 0.969 1.088 1.189 1.302 1.349 1.455
WINTER OUTDOOR CONDITIONS
Indoor Conditions
12ºC D
11ºC W
7ºC D
6ºC W
4ºC D
3ºC W
0ºC D
-1ºC W
-4ºC D
-6ºC W
-7ºC D
-8ºC W
Capacity kW