EasyManuals Logo

Midea MSH-07CR User Manual

Midea MSH-07CR
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Service manual
21
8. Installation details
8.1 Wrench torque sheet for installation
Outside diameter Torque
mm inch Kg.m
φ6.35
1/4 1.8
φ9.52
3/8 4.2
φ12.7
1/2 5.5
8.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Grade
Unit 7K 9K 12K 16K 18K
mm
2
1.0 1.0 1.5 2.5 2.5
8.3 Pipe length and the elevation
Pipe size
Capacity
Btu/h
GAS LIQUID
Standard
length (m)
Max.
ElevationB
(m)
Max.
ElevationB
(m)
Additional
refrigerant
(g/m)
3/8 (φ
9.52)
1/4 (φ
6.35)
5 5 10 30
7k~12K
1/2 (φ
12.7)
1/4 (φ
6.35)
5 5 10 30
1/2 (φ
12.7)
1/4 (φ
6.35)
5 8 15 30
5/8 (φ
15.88)
1/4 (φ
6.35)
5 10 20 30
18K~28K
5/8 (φ
15.88)
3/8 (φ
9.52)
5 10 20 65