10.7 MSH-16CR
SUMMER OUTDOOR TEMPERATURE DRY
Indoor Conditions
Total capacity kW 4.51 4.28 3.99 3.67 3.36 3.14
Sensitive capacity kW
3.43 3.25 3.00 2.78 2.56 2.40
21ºC D
15ºC W
Input kW. 1.44 1.56 1.69 1.81 1.94 2.06
Total capacity kW 4.83 4.62 4.35 4.08 3.82 3.58
Sensitive capacity kW
3.67 3.52 3.32 3.10 2.91 2.73
24ºC D
17ºC W
Input kW. 1.42 1.59 1.72 1.84 1.98 2.11
Total capacity kW 5.17 5.06 4.80 4.42 4.03 3.68
Sensitive capacity kW
3.87 3.85 3.74 3.32 3.06 2.76
27ºC D
19ºC W
Input kW. 1.48 1.61 1.74 1.88 2.02 2.16
Total capacity kW 5.41 5.36 5.28 5.11 4.87 4.63
Sensitive capacity kW
4.15 4.13 4.07 3.94 3.75 3.57
32ºC D
23ºC W
Input kW. 1.52 1.63 1.78 1.92 2.05 2.19
10.8 MSH-16HR
SUMMER OUTDOOR TEMPERATURE DRY
Indoor Conditions
Total capacity kW 4.51 4.28 3.99 3.67 3.36 3.14
Sensitive capacity kW
3.43 3.25 3.00 2.78 2.56 2.40
21ºC D
15ºC W
Input kW. 1.44 1.56 1.69 1.81 1.94 2.06
Total capacity kW 4.83 4.62 4.35 4.08 3.82 3.58
Sensitive capacity kW
3.67 3.52 3.32 3.10 2.91 2.73
24ºC D
17ºC W
Input kW. 1.42 1.59 1.72 1.84 1.98 2.11
Total capacity kW 5.17 5.06 4.80 4.42 4.03 3.68
Sensitive capacity kW
3.87 3.85 3.74 3.32 3.06 2.76
27ºC D
19ºC W
Input kW. 1.48 1.61 1.74 1.88 2.02 2.16
Total capacity kW 5.41 5.36 5.28 5.11 4.87 4.63
Sensitive capacity kW
4.15 4.13 4.07 3.94 3.75 3.57
32ºC D
23ºC W
Input kW. 1.52 1.63 1.78 1.92 2.05 2.19
WINTER OUTDOOR CONDITIONS
Indoor Conditions
6.36 5.65 5.00 3.23 2.70 2.60
15ºC
Input kW. 2.01 1.80 1.61 1.39 1.29 1.19
Capacity kW
5.99 5.36 5.27 3.35 3.09 2.78
18ºC
Input kW. 2.06 1.80 1.99 1.80 1.73 1.48
Capacity kW
5.46 5.42 4.80 2.92 2.63 2.56
20ºC
Input kW. 2.11 1.85 1.68 1.47 1.40 1.24
Capacity kW
5.53 5.27 4.57 2.48 2.64 2.52
22ºC
Input kW. 1.96 1.85 1.69 1.47 1.41 1.26