11.4 Trouble shooting (The Duct Type)
Fault or protection meaning
All lamps flashing at 5Hz
The PRO terminal on PCB of indoor unit without connected to Null line, or
optical coupler on PCB malfunction
Timer lamp flashing at
5Hz
Room temperature sensor malfunction.
Operation lamp flashing
at 5Hz
Evaporator temperature sensor malfunction.
Defrosting lamp flashing
at 5Hz
Condenser temperature sensor malfunction.
Alarm lamp flashing at
5Hz
Water-level checking malfunction.
Operation lamp and timer
lamp flashing at 5Hz
11.5 Trouble shooting (The Floor-standing Type)
Fault or protection meaning
T1, room temperature sensor, fault of open circuit, short circuit.
T2, pipe temperature sensor, fault of open circuit, short circuit.
Under cooling mode, T2 is on low temperature protection.
Under heating mode, T2 is on high temperature protection.