Problem solving guide
64
Issue Cause and remedy
Liquid has got into the
cooker hood.
Due to boiling over or spillage, liquid has made its
way through the extraction grille into the cooker
hood.
The base of the grease filter can hold approx. 250ml
of liquid. The drip tray underneath the housing can
hold a further 250ml of liquid.
Switch the cooker hood off.
Clean the grease filter, the drip tray and the inside
of the housing (see “Cleaning and care”).
Extraction performance
has decreased.
Extraction noise has
increased.
Objects (e.g. a cloth) have been drawn into the
cooker hood.
Switch the cooker hood off.
Remove the grease filter (see “Cleaning and care”).
Remove any objects from the grease filter.
The sensor control is
lit up.
The charcoal filter needs to be reactivated.
If the cooker hood is being operated in
Recirculation mode, reactivate the charcoal filter
as described in the operating and installation
instructions supplied with the recirculation box.
Reset the operating hours counter (see “Cleaning
and care” – “Resetting the charcoal filter operating
hours counter” in these operating and installation
instructions).
If the cooker hood is being operated in Extraction
mode, reset the operating hours counter (see
“Cleaning and care” – “Resetting the grease filter
operating hours counter” in these operating and
installation instructions).
The sensor control is
lit up.
The grease filter must be cleaned.
Clean the grease filter as described in “Cleaning
and care” –“Grease filter/Extraction grille”.