Supervisor level
38
The setting can be changed from 104-131°F (40°C55°C).
Factory default: 131°F (55°C)
Service
Clean out the airways
The tumble dryers electronic calculates the degree to which lint or detergent residues in
the lint filters and vent ducting are impairing performance. A message to check the con-
tamination appears. You can decide at what level of lint this reminder should be emitted.
If the message appears on the display even though the lint filter is clean, the vent ducting
is regarded as borderline. Miele recommends improving the vent ducting. Poor vent duct-
ing will result in longer program runtimes and greater energy consumption.
This reminder, which you can configure, is displayed: Clean out the airways
- Off
The reminder does not appear. However, if there is a very severe blockage in the ducting,
the program will be canceled regardless of this option.
- Heavy
The reminder only appears when there is a heavy build-up of lint.
- Factory default: normal
- Light
The reminder appears when there is only a small build-up of lint.
Clean the filters
The lint filter in the air-supply area must be cleaned on a regular basis. You can set an
hourly interval for the reminder.
The selected hourly interval depends on how much lint tends to build up and how often you
wish to clean the filter, e.g., for hygiene purposes.
You can adjust this reminder: Clean the filters
- Time interval of 5 – 55hours
- Factory default: after 55hours
- Off
Service interval
The tumble dryer shows a custom message at a selected interval to prompt you to under-
take specific maintenance tasks.
3 different messages can be created: 1/2/3. Each message is created in the language and
alphabet of the current supervisor language.
Your message is displayed at the end of the program and can be acknowledged with OK.
The same message appears at the end of the next program.
Settings
This setting allows you to determine the interval (by hours or date) at which the message
appears.
- Factory default: Off