Programme settings
106
Activating
conductivity
measuring
Conductivity measuring is activated individually for each programme.
Conductivity is measured in the final rinse phase.
...
LFMMc max. value
LFMMc max. value
Water intake
Water drainage
- Water intake
The electrical conductivity of the water before the beginning of the
final rinse phase is measured.
- Water drainage
The electrical conductivity of the water at the end of the final rinse
phase is measured.
Select an option using the and arrow buttons.
Press OK to save the setting.
Following selection a maximum limit value for electrical conductivity
must be set.
Set limit value
The limit values for Water intake and Water drainage are set
individually.
...
LFMMc max. value
Water intake or Water drainage
Set
Water intake
--
µS/cm
(5 - 200 µS/cm)
--
µS/cm
(5 - 200
µS/cm)
Water drainage
Adjustment is in increments of 1. The possible range is shown in the
bottom line.
Use the arrow buttons (higher) and (lower) to set the limit
value.
Touch OK to save the limit value.