Programming
142
3. Programme
stop signal 1
Used to set a "Programme stop" output (for signal transmitter) for a
programme stop.
Choose from the following options:
No
The output "Programme stop" is not activated for a programme stop.
Yes
The output "Programme stop" is activated for a programme stop.
4. Heating
Used to allow suppression of the heating.
Useful tip: This function can be used e.g. for warm rinses.
Choose from the following options:
Yes
The heating is activated normally in the heating regulation circuit to
reach the required temperature.
No
The heating is not activated. The selected temperature is to be
achieved exclusively via the water valve control. With the setting
Thermostop only "No" is possible. The field in the display for the
required temperature remains empty before and after programme
start.
5. Free
temperature
selection
Used to make changes to temperature before programme start.
Choose from the following options:
No
Always heated to the temperature set in the block programming.
Yes
The temperature of the 1st main wash set before programme start is
carried over to all programed blocks, but only if "Yes" is programmed
in those blocks in the "Free temperature selection" programme stage
and if the temperature programmed in the block is not lower.
6. Temperature
Used to programme a temperature.
Choose from the following options:
Cold
The heating is not activated.
15 to 95°C
With increments of 1°C temperature values are freely programmable.