Press multifunction button0/1.
Stop the pump by pressing button0/1, or the pump will stop
automatically after 60seconds.
Measure the required amount into the measuring vessel.
Enter the amount measured in field"V:".
The throughputP is calculated in ml/min by the controls.
Press the "Save" button.
The measured value is assigned to the pump.
Reattach the hose.
Cleaning and maintenance of the dispensing system
Rinse the dispensing system through with warm water every 2weeks,
or before shutting the dispenser pumps down for any length of time,
to avoid the system getting clogged up and corroded.
Also rinse out the siphons with water.
Put the siphons in a container of warm water (40-50°C).
Use dispenser calibration to activate each pump until the
dispensing system is rinsed through.
Check the connection points, hoses, dispensing sockets and
washers for leaks.