en - Installation
185
Drainage
Drain valveDV on machine side DN70, on-site socket DN70. Flow
rate temporary 200l/min.
If the slope for drainage is extremely steep, the piping must be vented
to prevent a vacuum from forming in the washing machine’s drainage
system.
Foam and vapour venting kitBWS
If excessive suds form, foam may escape from the vapour extraction.
To remove the foam, an optional vapour venting kit (BWS) can be
used.
Electrical connection
The electrical connection must only be carried out by a suitably quali-
fied electrician in accordance with local and national regulations such
as VDE (Germany), ÖVE (Austria) and SEV (Switzerland).
Tip: Open the machine lid. The connection points are located on the
machine frame.
When installing a residual current device (RCD) it must be TypeB.
The electrical components of this machine comply with
DINEN60335-1, DINEN50571.
See data plate for voltage data.
For hard-wired machines, an all-pole means of deactivation must be
provided on site. Switches with a minimum contact gap greater than
3mm are suitable disconnectors. These include circuit breakers,
fuses and contactors (VDE0660).
The plug connector or isolator switch should be easily accessible at
all times.
If the machine is disconnected from the electricity supply, the isolator
must be lockable or the point of disconnection must be monitored at
all times.
Observe the enclosed wiring diagram.