Cleaning the condenser unit
Detergent residue, hair and fine fluff
from the dryer can get through the fluff
filters and block the condenser unit.
Dust from the room in which the dryer is
installed can also get into the
condenser unit and cause a blockage.
Check the condenser unit at least
twice a year. If the dryer is used
frequently then clean the condenser
unit after approx. 100 drying cycles.
Removing the condenser unit
^ Open the door.
^
Open the service panel with the
yellow lever.
Hold the panel securely when doing
this.
^
Now remove the panel by pulling it
diagonally upwards and place it to
one side.
^
Turn the lever on the inner cover
downwards to the vertical position.
^ Pull the cover forwards.
^ Remove it by pulling it diagonally
upwards.
^
Turn the lever on the condenser unit
upwards to the vertical position.