Submenu containing different options:
Exit from submenu
Programs LOCK
Protection of programs P3 to P10
for all procediment against unintentional
change of:
• welding currents, slopes, timing
• Trigger selection 2T/4T
• Current reference EXT/Internal
• Pulsations
It is still possible to select different
programs and welding procediment.
Programs P1 and P2 are unlocked,
permitting full control of relative
parameters.
When pressing locked key pads or rotating
the encoder for locked parameters, the
display will flash “PG.L.” to remember the
active protection.
0 = unlocked (default setting)
1 = locked
Panel LOCK
Complete lock of box. All keypads
and Encoder are disabled.
When pressing locked key pads or rotating
the encoder, the display will flash “PA.L.” to
remember the active protection.
0 = unlocked (default setting)
1 = locked
2-times option for torch trigger
Permit to define 2 different ways
to control the retrigger of machine during
slope down. For detailed description of
different behaviours see the following
diagrams.
0 = return to welding current by step.
(default)
1 = return to welding current by slope up
4-times option for torch trigger
Permit to define 3 different ways
to control the torch trigger when the
machine is set as 4Times stroke (Lift or
HF). For detailed description of different
behaviours see the following diagrams.
Select a value in the range 0...2 (1=default
setting)
Dynamic Oxide Control.
0 = disabled
1 = enabled (default setting)
Remote Control Option
It is possible to select 4 different
ways depending from the external device
connected to 8-pole plug(option)
Welding current can be controlled up to
previous SET or to MAX
External reference voltage can be 0-10V or
0-5V
(Condition 2 & 3 presents lower resolution)
0 = 0-10V Æ Imin to I
SET
(default)
1 = 0-10V Æ Imin to I
MAX
2 = 0-5V Æ Imin to I
SET
(default)
3 = 0-5V Æ Imin to I
MAX
All the above settings will not be changed during
reset to factory settings