settings should be the same as the RS485 terminal devices.
Allow the device to collect RS485 data and upload the data.
1 bit/2 bit are available.
None, Odd and Oven are available.
1200/2400/4800/9600/19200/38400/57600/115200 are available.
The execution interval between each Modbus channel command.
The maximum response time that the UC300 waits for the reply to the
command. If it does not get a response after the max response time, it is
determined that the command has timed out.
Set the maximum retry times after device fails to read data from RS485
terminal devices.
Modbus RS485
bridge LoRaWAN
(LoRaWAN
®
Version Only)
If this mode is enabled, the device will transmit Modbus RTU commands
from network server to RS485 terminal devices transparently and send
Modbus reply originally back to the network server.
Port: Select from 2-84, 86-223.
3. Click to add Modbus channels, then save configurations.