EasyManua.ls Logo

Milesight WS202 - Downlink Commands

Milesight WS202
17 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Channel
Type
Value
Channel
Type
Value
01
75 (Battery)
64 => 100%
03
00 (PIR Status)
01=> Occupied
Channel
Type
Value
04
00 (Light
Status)
01=> Bright
5.3 Downlink Commands
WS202 supports downlink commands to configure the device. The application port is 85 by
default.
Channel
Type
Description
ff
03 (Set Reporting Interval)
2 Bytes, unit: s
10 (Reboot)
ff (Reserved)
Example:
1. Set reporting interval as 20 minutes.
ff03b004
Channel
Type
Value
ff
03 (Set Reporting
Interval)
b0 04 => 04 b0 = 1200s
= 20 minutes
2. Reboot the device.
ff10ff
Channel
Type
Value
ff
10 (Reboot)
ff (Reserved)
-END-