ALARM SIGNALS
EE: The instrument is provided with an internal check verifying memory integrity. The ALARM ‘’EE’’ flashes when a failure in
the internal memory is detected. In such case call the service.
P1: Probe alarm -P1- starts several seconds after the fault in the related probe. It automatically stops several seconds after the
probe restarts normal operation. Check connections before replacing the probe. In case of fault in the thermostat probe, the
starting and the stopping of the compressor are regulated thought parameters Con & COF.
HA: Maximum temperature alarm automatically stops as soon as the thermostat temperatures returns to normal and when
defrosting stops.
LA: Minimum temperature alarm automatically stops as soon as the thermostat temperature returns to normal and when
defrosting stops.
DEFAULT SETTING VALUES
Label
Name
Range
Value
Set
Set point
LS-US
4,0
Hy
Differential
0,1-25,5
O
C / 1-255
O
F
2,0
LS
Minimum set point
-50
O
C SET
58
O
F - SET
1.0
O
C
US
Maximum set point
SET 150
O
C
SET 302
O
C
5.0
O
C
Ot
Thermostat probe calibration
-12
O
C +12
O
C
-120 - +120
O
C
- 0,5
O
C
OdS
Outputs delay at start up
0 255 min
0
AC
Anti-short cycle delay
0 50 min
1
Con
Compressor On time with faulty probe
0 255 min
15
COF
Compressor OFF time with faulty probe
0 255 min
30
CF
Temperature measurement units
ο
C -
o
F
O
C
rES
Resolution
In : dE
dE
AgC
Agitator configuration
EL = with compressor
In = independent
EL
tIC
Resolution for the Agt parameter
nP = minutes
Pb = seconds
nP
IAg
Interval between agitation cycle
1 120 min
15
Agt
Length for agitation cycle
0 255 min
3
APO
First agitation cycle after start up
n= immediately
y= after IAg
Y
ALc
Temperature alarms configuration
rE Ab
Ab
ALU
Maximum temperature alarm
ALL-150
O
C
ALL-302
O
F
100
ALL
Minimum temperature alarm
-50.0
O
C-ALU
-58
O
F-ALU
-50
ALd
Temperature alarm delay
0 255 min
15
dAo
Delay of temperature alarm at start up
0 23 h & 50 min
1,3
PbC
Probe selection
Ptc-ntc
ntc
Srt
Initial regulation time
0 59min
0
SrS
Initial regulation Set point
-55,0
O
C 150,0
O
C
15
rEL
Software release
-
3,0
Ptb
Map code
-
2
*Hidden parameters