Milli-Q IQ 7005 Specifications

General IconGeneral
Flow RateUp to 2 L/min
Pyrogens (Endotoxins)< 0.001 EU/mL
DisplayTouchscreen
ModelIQ 7005
Water TypeUltrapure (Type 1) water
Purity Level18.2 MΩ.cm
Resistivity18.2 MΩ·cm @ 25 °C
TOC≤ 5 ppb
Particles > 0.22 μm≤ 1 particle/mL
Bacteria<1 CFU/mL
ConnectivityUSB, Ethernet
Power Supply100-240 V AC, 50-60 Hz
TypeUltrapure Water Purification System

Summary

Introduction

System Identification

Details system models, catalogue numbers, voltage, and frequency for the Milli-Q IQ series.

Intended Use

Specifies the system's purpose for producing pure and ultrapure water for laboratory research and quality control.

System Overview

System Components

Identifies and illustrates the various units comprising the Milli-Q IQ water purification system.

Description of the System

System Flow-Schematics

Provides graphical representations of the production and distribution hydraulic systems with component labels.

Quick Start Guide

Exit Screensaver

Explains how to wake the system display from the screensaver mode using touch or dispense wheel.

Dispense Ultrapure Water (Q-POD)

Guides users on dispensing ultrapure water using the Q-POD dispenser, including recirculation and flow adjustment.

Dispense Pure Water (E-POD)

Guides users on dispensing pure water using the E-POD dispenser, including recirculation and flow adjustment.

Volumetric and Assisted Dispensing

Details automatic and assisted volumetric dispensing procedures for precise water delivery.

Dispense Report Management

Describes how to view, personalize (add user ID), and export dispense operation reports.

Alerts and Alarms Management

Instructs on viewing, understanding, and managing system alerts and alarms for maintenance and issues.

Navigate Screen Interface

Explains how to navigate the POD touch-screen interface, including menus and icons.

System Apps and Pops-ups

Covers accessing system applications, managing pop-up windows, and using the on-screen keypad.

Consumable Menu

Viewing Consumables Status

Shows how to check the status of installed consumables via color-coded icons and provides ordering info.

Consumable Identification

Explains the process of identifying and scanning consumables using system cards.

Information Menu

System Information

Provides access to system details, lab information, user manual download, and legal notices.

History and Reports

Details how to access, preview, and export daily quality and dispensing event reports.

Flow Schematic

Displays a graphical representation of the system's hydraulic components and their status indicators.

Troubleshooting Guide

Offers diagnostic summaries, system info, and troubleshooting steps for effective problem resolution.

Contacts and Support

Lists contact information for technical support, application specialists, and system managers.

Settings Menu

System Configuration

Allows adjustment of system parameters like screensaver duration and lab close mode for energy saving.

Production Configuration

Covers settings related to periodic EDI rinsing for system performance and water quality.

Tank Configuration

Options for managing tank capacity and setting refill parameters for water storage.

Distribution Configuration

Settings for recirculation, safety flow stop, and dispensing modes to manage water distribution.

Production Alarm Configuration

Configuration settings for alarms related to production parameters like resistivity and conductivity.

Tank Alarm Configuration

Configuration settings for alarms related to tank status, such as tank empty.

Distribution Alarm Configuration

Configuration settings for alarms related to distribution parameters like flow rate.

Connectivity Settings

Options for network connection via Ethernet and remote access to the system interface.

Date, Time & Language Settings

Configuration for system date, time, timezone, and user interface language.

Password Management

Manages system access, password settings, and system manager profiles for security.

Units Configuration

Allows formatting of units for resistivity, temperature, pressure, and storage tank levels.

Maintenance Menu

Install Consumables Wizards

Guides through the step-by-step process of installing system consumables like IPAK Gard and Quanta.

Pack Replacement

Step-by-step visual guide for removing and installing IPAK Gard and IPAK Quanta packs.

Application POD-Pak Installation

Procedure for installing specific POD-Pak consumables, including rinsing steps.

Cleaning and Sanitization

Instructions for cleaning inlet strainers and sanitizing the A10 TOC Monitor cell.

Depressurization Procedure

Details how to temporarily stop production and water processes, often for leak management.

UV Lamp Maintenance

Information and safety precautions for maintenance and replacement of UV lamps.

Self Help Guide

Depressurize System

Guides on depressurizing system sections for leak management and safe handling.

Turn System Off

Instructions on safely powering down the system and unplugging the power cord.

Inaccurate Volumetric Dispensing

Explains common causes and solutions for inaccurate volume dispensing, including flow meter offset.

High TOC Values

Provides recommendations for addressing high Total Organic Carbon levels, including pack replacement and monitor cleaning.

Low Flowrate Issues

Troubleshooting steps for reduced water flowrate, checking POD-Pak and air vents.

Tank Not Refilling

Steps to diagnose and resolve issues with the water storage tank not refilling, checking alarms.

Requirements and Specifications

Water Specifications

Details quality parameters for Elix, Product, and Element water, and relevant international standards.

Feed Water Requirements

Lists the required parameters for the incoming tap water supply for optimal system operation.

System Specifications

Covers electrical requirements (voltage, frequency) and environmental conditions for system operation.

Communication Features

Describes USB, Ethernet, RFID, and software communication capabilities for system interaction.

Dimensions and Weights

Provides physical dimensions and weight specifications for the water purification units and storage tanks.

Ordering Information

Lists catalog numbers for system accessories and consumables for easy ordering.

Legal Information & Warranty

Product Warranty and Liability

Outlines the terms of product warranty and limitations of liability as per purchase agreement.

Trademarks

Lists the registered trademarks associated with the product, company, and related technologies.

Safety Information

Crucial safety warnings, high voltage hazards, PPE, and installation guidelines for safe operation.