Preventive Maintenance
PELLERIN MILNOR CORPORATION
Speak to your Milnor dealer or the Milnor factory if you see corrosion damage.
CAUTION 4 : Risk of damage—The inverter will burn out without sufficient airflow.
Keep fans, filter, and vents clean (see Figure 1).
Tip: Put streamers in front of the fan to make sure the fan operates.
Figure 1: Electrical Box and Inverter
Example: 48040F_ Example: 30022X_
Legend
1. Clean the air filter on the electrical box door.
2. Clean the fan on the electrical box door.
3. Clean the cooling vanes and vents with a vacuum.
.
2. Lubricant Procedures
CAUTION 5 : Risk of damage—Lubricant that is dirty or the incorrect viscosity will
decrease the life of bearings and hydraulic components. Lubricant that is spilled on a component
(for example, the drive belt) can cause failure of the component.
Speak to the lubricant manufacturer before you apply lubricant that is not specified in this
instruction.
Do not mix petroleum and synthetic lubricants.
Clean the grease fittings before you apply grease.
Clean spilled lubricant.
CAUTION 6 : Risk of damage—The force of a grease gun can push out the bearing seals.
Use a hand grease gun. Do not use a power grease gun.
Add only the specified quantity of lubricant.